{"id":362993,"date":"1970-01-01T00:00:00","date_gmt":"1969-12-31T22:00:00","guid":{"rendered":"https:\/\/staging.met-industry.hu\/?post_type=product&#038;p=362993"},"modified":"2026-09-13T00:23:45","modified_gmt":"2026-09-12T22:23:45","slug":"tsh-004-indito-generator-es-szabalyzo-teszter","status":"publish","type":"product","link":"https:\/\/met-industry.hu\/en\/uzlet\/tsh-004-indito-generator-es-szabalyzo-teszter\/","title":{"rendered":"TSH-004 Starter , Alternator &amp; Regulator Tester"},"content":{"rendered":"<p># Rotrix TSH-004 Starter, Generator and Regulator Tester<\/p>\n<p>The Rotrix TSH-004 is a professional diagnostic device specifically designed for the comprehensive functional testing of 12V and 24V automotive starters, generators (alternators), and voltage regulators. This tester is an ideal choice for workshops, repair shops, spare parts dealers, and educational institutions where reliable and accurate measurement is essential during maintenance and repair processes.<\/p>\n<p>The TSH-004 enables the simulation of generator performance under load, independent testing of voltage regulators, and measurement of starter motor performance at idle speed.<\/p>\n<p>## Main Application Areas<\/p>\n<p>This versatile test bench provides indispensable assistance in the following areas:<\/p>\n<p>*   **Repair Shops (Manufacturing Plants):** Determining the technical condition of starter motors and generators before and after maintenance, ensuring professional repair.<br \/>\n*   **Service Stations (Auto Repair Shops):** Assessment of the condition of removed units to decide on future usability.<br \/>\n*   **Spare Parts Trading Organizations:** Pre-sale unit inspection, significantly reducing the risk of warranty returns.<br \/>\n*   **Educational Institutions:** Providing practical training on the repair technologies for starter motors and generators.<\/p>\n<p>## Featured Characteristics and Advantages<\/p>\n<p>During the design of the TSH-004, user-friendly operation and reliability were the central focus:<\/p>\n<p>*   **Compact Design:** Ideally suited for desktop placement due to its small dimensions.<br \/>\n*   **Simple Power Supply:** Operable from a single-phase 230V mains socket.<br \/>\n*   **Tool-Free Mounting:** Convenient and fast fixing of the unit and the drive without extra tools.<br \/>\n*   **Finely Adjustable Parameters:** Allows stepless adjustment of the generator speed and load current to simulate real-world test conditions.<br \/>\n*   **Diagnostics of Generators Without Integrated Regulator:** Capable of testing generators that do not have a built-in voltage regulator.<br \/>\n*   **Electronic Self-Protection System:** Protects the test bench's electronic components from damage caused by incorrect wiring.<\/p>\n<p>## Technical Data and Specifications<\/p>\n<p>The precise and detailed technical data of the TSH-004 tester ensures the accuracy of the diagnosis:<\/p>\n<p>| Parameter | Value | Remarks |<br \/>\n| :&#8212; | :&#8212; | :&#8212; |<br \/>\n| **Dimensions (L\u00d7W\u00d7H)** | 570 \u00d7 505 \u00d7 450 mm | Compact desktop design |<br \/>\n| **Weight** | 70 kg | Stable construction |<br \/>\n| **Supply Voltage** | 230 V (60Hz) or 120 V (50Hz) | Selectable mains input |<br \/>\n| **Power Supply Type** | Single-phase | Standard mains connection |<br \/>\n| **Drive Power** | 2.2 kW | Powerful drive for the load |<br \/>\n| **Number of Batteries (Not Included)** | 2 pcs | Similar 12V lead-acid batteries |<br \/>\n| **Battery Capacity** | 45 Ah \u2013 60 Ah | Maximum size: 207\u00d7175\u00d7175 mm |<br \/>\n| **Automatic Battery Charging** | 1st unit: Yes, 2nd unit: No | Only one battery can be charged from the device |<br \/>\n| **Nominal Voltage of Diagnosed Units** | 12 V, 24 V | Wide compatibility range |<br \/>\n| **Drive Type** | Belt (V-belt \/ Poly V-belt) | Flexible belt type support |<br \/>\n| **Drive Speed** | 0 \u2013 3000 rpm | Steplessly adjustable |<\/p>\n<p>### Generator (Alternator) Diagnostics<\/p>\n<p>The TSH-004 is capable of assessing the technical condition of 12V and 24V generators under load:<\/p>\n<p>*   **12V Generator Loading:** 0 \u2013 100 A<br \/>\n*   **24V Generator Loading:** 0 \u2013 50 A<br \/>\n*   **Load Regulation:** Stepless (0-100%)<br \/>\n*   **Drive Speed Regulation:** Stepless<\/p>\n<p>**Diognosable Generator Types:**<br \/>\nCOM (LIN, BSS), P-D, RLO, C, SIG, F\/67<\/p>\n<p>**Measured Parameters for Generators:**<\/p>\n<p>*   Stabilization voltage<br \/>\n*   Alternating Current (AC)<br \/>\n*   Direct Current (DC) \/ Continuous Current<br \/>\n*   Drive Speed<\/p>\n<p>**COM Voltage Regulator Specific Diagnostics:**<\/p>\n<p>*   Protocol Identification<br \/>\n*   Data Transfer Rate<br \/>\n*   Identifier (ID)<br \/>\n*   Type<br \/>\n*   Error codes<\/p>\n<p>### Voltage Regulator Diagnostics<\/p>\n<p>Independent testing of the regulators is essential to isolate generator malfunction:<\/p>\n<p>**Diognosable Voltage Regulator Types:**<br \/>\nCOM (LIN, BSS), P-D, RLO, C, SIG<\/p>\n<p>**Checked Parameters:**<\/p>\n<p>*   Stabilization voltage<br \/>\n*   Checking the operation of the charge indicator lamp circuit (D+)<\/p>\n<p>**COM Voltage Regulator Specific Checks:**<br \/>\nThe same communication parameters as for generator diagnostics (Protocol, Speed, ID, Type, Faults).<\/p>\n<p>**Short Circuit Protection:**<br \/>\nHas built-in short-circuit protection and alarm for safe operation.<\/p>\n<p>### Starter (Motor) Diagnostics<\/p>\n<p>The TSH-004 is capable of measuring the performance of 12V\/24V starter motors under no-load conditions:<\/p>\n<p>*   **Diognosable Starter Motor Power:** Maximum 4 kW<\/p>\n<p>**Measured Parameters for Starter Motors:**<\/p>\n<p>*   Voltage (Voltage)<br \/>\n*   Alternating Current (AC)<br \/>\n*   Direct Current (DC) \/ Continuous Current<\/p>\n<p>## Category and Brand<\/p>\n<p>*   **Category:** Test equipment (Test equipment)<br \/>\n*   **Brand:** Rotrix<\/p>\n<p>A Rotrix TSH-004 Starter, Alternator &#038; Regulator Tester a modern j\u00e1rm\u0171jav\u00edt\u00e1si ig\u00e9nyekre szabott, robusztus \u00e9s megb\u00edzhat\u00f3 megold\u00e1s, amely garant\u00e1lja a be\u00e9p\u00edtett elektromos komponensek gyors \u00e9s pontos \u00e1llapotfelm\u00e9r\u00e9s\u00e9t.<\/p>","protected":false},"excerpt":{"rendered":"<p>Professional Rotrix TSH-004 diagnostic device for testing 12V and 24V automotive starters and generators.<\/p>","protected":false},"featured_media":350477,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[366],"product_cat":[12998],"product_tag":[],"class_list":["post-362993","product","type-product","status-publish","has-post-thumbnail","product_brand-stremtec","product_cat-egyeb-termekek","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product\/362993","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/comments?post=362993"}],"version-history":[{"count":1,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product\/362993\/revisions"}],"predecessor-version":[{"id":381823,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product\/362993\/revisions\/381823"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/media\/350477"}],"wp:attachment":[{"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/media?parent=362993"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product_brand?post=362993"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product_cat?post=362993"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/met-industry.hu\/en\/wp-json\/wp\/v2\/product_tag?post=362993"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}